Brand Name : Fullde

Model Number : LB-26KVA-120V/230V

Certification : CE, ISO9001

Place of Origin : Dongguan,China

MOQ : One Set

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 100sets per month

Delivery Time : 20 working days

Packaging Details : Standard Export Wooden Case

Insulation grade : F Class

Cooling : Forced air cooling, Horizontal inlet air, Upward cooling

Rated Frequency : 50/60Hz

Dimensions : 750*850*1300mm

Rated Voltage : DC750V

Power Factor : 0.8~1

Contact Now

26KVA Resistive Reactive Load Bank Work Both in the Voltage of 120V and 230V

Fullde powered load banks solutions provides a complete line of load banks for commercial,industrial and residential application.We specialize in providing a wide range of well known and trusted brands of load banks, supplying load banks at competitive prices.Our many years of experience in the load banks market,enables us to provide a tailor made solution specifically for you.

The Load Bank is designed for testing, maintenance, and performance analysis of very high capacity electrical loads of large AC power systems. The load bank is a self-contained unit providing resistive and inductive loads to 1500KVA at 0.8 power factor. Multiple units can be paralleled to achieve virtually any total capacity desired.

Multifunction:

* Advanced components
* Durable and reliable
* Integrated & modularization design, easy to transport

1. Control mode: (1) manual control (2) remote control (3)software control

2. Display function: voltage, current, frequency, power factor, active power, reactive power, apparent power etc...

3. Protection function: overvoltage, overcurrent, overheat, over low blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.

4. Forced air cooling: industrial heavy duty fan,forced air cooling, horizon air intake, upwards outlet, low noise.

5. Power consumption components: made by special alloy resistance, high temperature resisting, high heat dissipation capability, high heat stability, no naked light, safety and reliability. Running temperature is 1/3 of rating.

6. Rain-proof structure: containerized structure provides ultra protection, protection grade higher than IP55.

7. Material and coating: the body adopt cold-rolled steel plate that processed by galvanizing corrosion protection, powder coated and spray paint.

8. Load bank features world-famous components to ensure reliable performance and longer service life including:
Switch: ABB, Siemens and Schneider; PLC: Panasonic and Siemens.

9. Software control: it can test and display voltage, current, frequency, power factor, active power, reactive power, apparent power etc, the test result can be store & print and form all kinds of curve, chart and test report.

Technical Parameters for reference:

System components Load bank, resistive load,data collection, automatic control and manual control, electrical control, cooling devices and auxiliary control,Industrial machines, printer.
Resistive load stalls(300KW) resistive step:5A
reactive step:5A
Test voltage Three-phase AC480V;
Test Frequency 50Hz;
Resistance tube Insulation resistance of each resistor above DC500V 100MΩ , Pressure AC2000V 1 minute, Resistance to high temperature.
Load connection Star (three-phase four -wire)
Loading precision ±3%;
Work way Continuous work
Working power 480VAC/50Hz/Three-phase four-wire system; (reservation terminals)
Operator terminal IPC / software, full realization of automated control
Control mode Manual control / computer software auto control
Measured Control Function Load subtraction control, extended load automatic identification synchronization control
IPC detection function I, V, HZ, KW, COSΦ etc.Real-time display, electrical performance testing, curves and report output, system electrical parameters monitoring, automatic data acquisition;
Parameter record Form through EXCEL, curves pictures saved by WORD document
Parameter display three-phase voltage, three- phase current, apparent power, active power, reactive power, power factor, frequency, etc.;
Load protection Overvoltage, overcurrent, high temperature, air flow and fan failure protection;
Fault alarm Fan failure, load high temperature alarm
Size 750*850*1300
Weight 150kg
Applicable Scope For marine diesel generator sets, land diesel generators, power inverters, UPS systems

Shipping:

26KVA 120V Resistive Reactive Load Bank With Good Dissipation Performance


Product Tags:

reactive load bank

      

capacitive load bank

      
Quality 26KVA 120V Resistive Reactive Load Bank With Good Dissipation Performance for sale

26KVA 120V Resistive Reactive Load Bank With Good Dissipation Performance Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Fullde Electrical Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)